 +8618999222000  875491817@qq.com
Homepage / news / Technical Support

Recommended Products

Technical Support

  • Mar
    29
    Good condition required for engine startup
    Good conditions needed when engine start: (1) There is enough start speed. The starting speed is high, the amount of gas in the cylinder is small, and the heat transfer of the compressed air to the cylinder wall is short, and the heat loss is small, the gas temperature and pressure when the compression is finalized. Generally requiring a speed of 100R / min. (2) The sealing property of the cylinder is good. This can further reduce the amount of leakage to ensure that the gas has sufficient combustion temperature and pressure when the compression is terminated, and the compression pressure of the cylinder shall not be lower than the standard value of 8_0_%. (3) When the mating gap between the engine relative to the running machine is appropriate, and the lubrication is good. ⑷ The battery must have sufficient starting capacity, and the technical condition of the start circuit is normal. ⑸ The amount of starting oil meets the requirements, the injection quality is good, and the injection advance angle should meet the requirements. ⑹ Use fuel that meets the requirements. More information can be consulted with our company's technical department: 0991-3817210, 0
  • Mar
    29
    Five Canal Shui Plant Technical Service Information Form
    Our company provides Xinjiang five channels self-come water plant a 600KW of China-British joint venture Cardo diesel generator set, model TAD61 / Starlight TFW-600KW, this diesel generator set has been installed, running is normal, customer satisfaction, please consult our company After-sales service department: 0991-3817210, 0991-3814032, 0991-3856119
  • Mar
    29
    What is the advantage of other brand generator groups, what is the advantage of Cummins generator group?
    Cummins is a company designed, produced and sells diesel engines and compressed natural gas engines. Cummins invest more than 10 million US dollars in China, as foreign investors in the Chinese engine industry, and Cummins has eight joint ventures and sole proprietorship manufacturing companies in China. Cummins generator group advantage 1: After several Cummins generator sets, a considerable power generator set is powered to the load, and the number of machines can be determined according to the size of the load (the generator set is under the operating capacity of 75%. The fuel is low), thereby saving diesel, reducing the purpose of the cost of generator sets. In particular, the current diesel is more tight and the speed of oil is rapid, and the diesel has become quite important. Essence of Cummins Power Generator: Realizing Uninterruptible Power Supply Supporting Factory Normal production, when the unit conversion is used, the standby generator set can be turned on, then stop the original running generator set, there is no need to power out the power. Cummins generator set advantages
  • Mar
    29
    Why is the diesel engine unstable?
    According to the maintenance personnel of our diesel generator group, the experience of the diesel engine is unstable, and there may be as follows: 1. Air or water solution in fuel: Exhaust the fuel system. Nozzle assembly failure solution: Replace the nozzle assembly 3. Papers adjustment or oil blocked solution: Adjusting the throttle or cleaning oil road 4. Rate converter or a weekly failure solution: Replace the Rate Converter or Week时间 5. Electronic governor fault solution: Check the electronic governor and speed perception 6. Diesel generator set operation vibration too large solution: Check unit shock absorbing equipment 7. Diesel generator set load too large solution: remove Partial load 8. Fuel filter failure solution: Check fuel filter 9. Fuel pump fault solution: Check the fuel pump
  • Mar
    29
    What do you need to pay attention to what generator sets in operation?
    What matters need to pay attention to in the operation of the diesel generator set? Our company's technical staff is summarized as follows: Working Please pay attention to the following points: AC current table: Whether the table needle indicates normal, switching the current switching switch, measure the phase of each phase between each phase Do not exceed 10% of the phase differences between each phase ordered. 2. AC voltage meter: Whether the voltage indicated by the table needle is normal. 3. The hydraulic pressure indicated by the oil pressure gauge is in the normal range. 4. Charge table: Whether the pointer is in the direction of (+). 5. Whether the water temperature indicated by the water temperature surface is in the range of normal 65 ° C to 93 ° C. 6. Turndometer: Whether the number of engines is appropriate. (50Hz is 1500 rpm) 7. The generator engine has no abnormal sound or vibration. More related information, see the official website of Starlight Generator: www.xjxgdl.com Star Group Xinjiang area demolition generator set sales hotline: 18999222
  • Mar
    29
    How to properly use common generators?
    How to properly use common generators? Our company's technical department summarizes the following points, please read it in detail! Some diesel generators are continuously carried out for a certain period of time or often as a commonly used power supply for electricity load, which is referred to as a common diesel generator set. Common diesel generator sets can serve as a common unit and a spare unit. The long-term diesel generator sets have long working hours, large-purpose curves, and the selection of unit capacity, number of tables, and the selection of the unit and the control method of the unit are different from the emergency unit. 1. The determination of the capacity of common diesel generator sets The long-term continuous operation of the unit can meet the full engineering calculation load selection, and the capacity of the generator sets should be determined according to the importance of the load. The output power of the commonly used diesel generator set is generally 0.9 times the calibration power. 2. The determination of the number of common diesel generator sets often use the number of diesel generator sets
  • Mar
    29
    Advantages of Starbor Group Gas Generator Set
    The products produced by Jiangsu Xingguang Power Equipment Co., Ltd. have the following features: 1) Adapt to the low-calorie gas, guarantee good combustion, guarantee the smooth operation of the machine; 2) Apply extremely low pressure to gas, do not have to boost, reduce investment and Improve effective power generation, no need to establish a gas storage tank; 3) The unit has a self-contained system, and the auxiliary equipment is less; 4) The unit can be used in a single table, and can be used in combination with the machine, and can be accessed; 5) The unit quality is reliable. Low speed, small mechanical load; 6) The main controls are all adopted by the world's advanced importing components; 7) The various protection systems of the unit are complete.
  • Mar
    29
    Diesel Generator Set Coolant Use \"Compass \"
    With the improvement of diesel engine enhancement, the demand of the diesel engine on the cooling medium is also improved, so how should I choose cooling water? The generator set Knowledge Base will introduce you to the choice of cooling water of diesel engine. When the diesel engine works, the normal temperature of the cooling water should be maintained at 75 ~ 90 ° C, at which time the diesel engine can make maximum power, the fuel consumption will be close to the economic state, and the strength of the parts is also low. If the temperature of the cooling water is too high or too low, or if you remove the thermostat, the function of the cooling system will reduce or lose. Because the diesel engine is working, the fuel combustion will release a large amount of thermal energy, and the gas temperature in the cylinder is as high as 1800 ~ 2000 ° C, while only 30% to 40% in the thermal energy generated by the combustion is mechanically, about 20% ~ 25% cooling system. take away. If the cooling system is abnormal, the temperature of the cooling water is too high or too low, which will not only affect the normal work of the diesel engine, or even a fault.
  • Mar
    29
    The generator instruction manual is too cumbersome? This is simple!
    Many users think that the operating instructions of the generator set will be too cumbersome, and ask our company's after-sales department of the engineer as simple and correct, and now our company engineers make the following simple operating instructions! Preparation 1 before the diesel generator set 1, check if the liquid level is normal 2, check if the oil is full of online 3, check if the battery power is sufficient 4, except for the operator of the generator set, other people should stay away from the generator set to prevent accident occurrence The diesel generator set starts 1. Loosen the hand pressing pump backhaul direction, manual oil pump, open the oil pump, and exhaust the air. 2, open the throttle switch to the ON position, the engine starts 4, step by step, observe the HZ table to 50-51 position, V table to 380-400 position 5, push the main switch to the IN position closing power generation unit stop Message 1, when the stop should first cut off the main air switch to the OFF position 2, step by step to minimize the throttle, easy to stop the parking switch, power generation
  • Mar
    27
    Generator set simple operating instructions
    Diesel generator sets simple precautions and operational processes 1. Note: 1. Diesel generator set should be equipped with a battery charger. Regularly check if the battery is lost, and charge it. The battery will be charged through the randomly equipped charging generator during the operation. 2, regular inspection machine oil, diesel, water, antifreeze, etc. Is enough 3, to functionally and stable normal operation, should be replaced, die filtration, air filtering, etc. 4, try to ensure that the temperature is at least 0 ° C, which is easier to start when the unit is started, and the second, manual startup and stop mode 1, first open the DC power switch on the controller, and the film data is displayed normally. 2. Press the manual key (the hand button), to wait in the manual mode indicator. 3. Press the start button (green button), and then the fuel relay after 1S clock, then the unit starts. 4. After the unit is raised from a low speed to the high speed, the film will be displayed normally, waiting to carry \", at this time
  • Total 53 pages  Go to Page
  • Go
Urumqi Cummins Electromechanical Equipment Co., Ltd.
Urumqi Cummins Electromechanical Equipment Co., Ltd.
a professional production of generators.
Dieselgenerators Diesel generator setsManufacturers, Supply Cummins generator sets, Yuehai generator sets, Yuchai generator sets.
Contact Us
Address:Room 2-4-602, Jiafengyuan Community, No. 305, Beijing North Road, Urumqi, Xinjiang
Contact: Gu Xiaobing
Managed Office: +86-0991-3817210 +8618999222000
Sales: +86-0991-3814032 +8618609915083
Three packs: +86-0991-3814032 +8617704919966
Website:
www.xjxgdl.com
mailbox:3481400475@qq.com
Copyright ©Urumqi Cummins Electromechanical Equipment Co., Ltd.New ICP No. 17000509 -1