    Diesel generator set lubrication system and cooling system introduction
    (1) The function of the lubrication system lubrication system is to provide sufficient oil to each friction surface of the diesel engine to reduce its wear and ensure its normal operation. At the same time, there is also a role of heat dissipation, cleaning, sealing and corrosion. The lubrication system is mainly composed of an engine oil pump, an oil filter, a centrifugal filter, a variety of regulatory valves and a lubricating pipeline oil cooler. (2) The main function of the cooling system cooling system is to take out the heat generated by the engine operation by the cooling medium, ensuring that the engine operates within the most reasonable temperature range. Depending on the different cooling medium, it can be divided into water-cooled and air-cooled. Water cooled is divided into natural circulating cooling and forced circulation cooling, which can be divided into open and closed. In the open-in-in-circuit enforcement circulation cooling system, the cooling medium is directly connected to the atmosphere. In the closed-enforced circulation cooling system, the cooling medium is not directly related to the outside air atmosphere.
  • Feb
    18
    Diesel generator set fuel system and intake exhaust system
    (1) Fuel supply and speed control system: The fuel supply system is mainly composed of components such as oil pump, fuel filter, fuel cooler, fuel injection pump and injector. Its function is to spray diesel into the combustion chamber according to the requirements of diesel engine conditions, timing, quantitative, and regularly. At the same time, by the action of the fuel injection pump and the governor, the diesel engine is stably operated at a given condition. Common fuel supply and speed control system mainly have plunger fuel feed pump fuel supply and speed control system, PT fuel supply and speed control system, electric control injection (including high pressure common rail) fuel supply and speed control system, etc. (2) Inlet exhaust system: The intake system of the diesel engine is mainly composed of air cleaner, intake exhaust pipe, muffler, and boosting system. Jiangsu Xingguang Power Equipment Co., Ltd. was founded in 1974 and is one of the earlier manufacturers of domestic generator sets. With 64 sales in the country
  • Feb
    15
    Introduction to the definition and characteristics of high pressure diesel generator sets
    Diesel generator sets have high pressure diesel generator sets and low pressure diesel generators. What is a high pressure diesel generator set? In fact, it means literally, high voltage. At present, many large enterprises, coal mines, power plants, ports, airports, data centers, etc. are relatively more than procurement of high-pressure diesel generator sets. The high-pressure diesel generator sets we have said is generally divided into 6kV and 10kV. Low-pressure diesel generator sets are generally a common 230 / 400V diesel generator set on the market. High-pressure diesel generators generally do according to customer requirements. High-pressure diesel generator sets have diesel, heavy oil. High pressure diesel generator sets high pressure regulation accuracy, good dynamic performance, large capacity, long-distance power supply. The voltage waveform distortion is small, the maintenance is convenient, and the service life is long. Of course, the high-voltage generator is used as high-voltage generators, so the increase in voltage level makes its insulation requirements.
  • Feb
    15
    Reasons for the flameout during the working process of diesel generator sets
    The diesel generator is suddenly turned off during the work, mainly fault causes and solutions: 1. When the diesel generator is automatically turned off, the speed gradually decreases, the operation is unstable, and the exhaust is white smoke. This phenomenon indicates that there is water, cylinder in diesel. The pad is corrupted, or the automatic decompression is damaged. Measures: Replace the cylinder pad and adjust the decompression mechanism. 2, the exhaust pipe is black, the gas doors are not working properly. This situation is caused by poor combustion in diesel generators. The main reason is that the air filter airway is seriously blocked, causing intake insufficient. Measures: The air filter should be cleaned, and the intake pipeline should be cleaned to ensure that the air is sufficient. 3, when automatic flameout, running continuous and unstable, with an abnormal knock, this phenomenon belongs to sudden mechanical failure, its common cause: crankshaft break, piston pin break, link bolts loose or broken, valve Lock, pneumatic card spring falling, gas
  • Feb
    14
    Diesel generator set water tank leakage
    During the use of diesel generator, if there is a water tank, how to check and repair? Jiangsu Xingguang Power Equipment Co., Ltd. technical service engineer gives the following treatments: 2, liquid closure glue. If it is created due to solid gasket, the leak surface can be cleaned, and then the liquid closure can be applied. 3, lacquer film. If the seam is leaking, soak the lacquer in alcohol, and clean the seams, apply the paint piece to the seam. 4, sticking. If it is a water tank or a water tube crack or a gas hole causes a small leak, we can clean the leakage site and then apply the adhesive glue. 5, padding. If it is a joint that leaks here, we can add a thin plastic pad on both sides of the leak-proof circle, tighten it hard. River
  • Feb
    14
    Preventing the creation of \"stop \", pay attention
    Diesel generator sets as an emergency spare power supply after power failure, most of the time crew is in standby spare. After the electric power failure, the unit needs \"Starting, and powered up immediately.\" Daily to strengthen the maintenance and maintenance of the generator set is critical, as the unit is in a static, itself is complicated with oil, cooling water, diesel, air, etc., the crew occurs,\"stopping \"The phenomenon. 1. Water enters the diesel engine due to condensation in the air in the air, the water is formed in the inner wall of the tank, flowing into the diesel, causing the diesel water content to exceed the standard, such diesel enters the engine high-pressure oil pump, rust precision coupling - Plunger, severe damage unit, regular maintenance is effective and avoidable. 2, the maintenance of the engine oil (one year) engine oil is mechanical lubrication, while the oil has a certain stay period, long time
  • Feb
    14
    Difference of the speed of the diesel generator set and the ship's generator set
    The work of the diesel generator is a loop process, then a unit is required to describe the metrics of this job during continuous loop operation. Generally, we are represented by the number of rotations per minute, called the speed. Radiation of diesel generator sets We generally use rot / division, ie r / min. Of course, the use of diesel engines is different, and the required speed is also different. The fixed equipment includes a diesel generator set, a water pump unit, and the like, and the transfer speed used is generally fixed, such as the 50Hz diesel generator set of 50 Hz diesel generated by 1500r / min. The speed of the marine diesel engine is low, and if the speed is higher than 1000R / min, it can be called a high-speed diesel engine. And some large ship's diesel engine may have only 100 turns per minute. For diesel generators, it is also important to maintain a reasonable speed, it can
  • Feb
    14
    The advantages of the use of the parallel generator set
    What are the advantages of the diesel generator set? First we need to understand what is the panel of the diesel generator set. The cabinet is also a generator automatic control cabinet. When two and above, the power generator set is powered together to power supply, or when one or more generator sets are powered together to power supply, the diesel generator is required to achieve the requirements of the joint power supply, so that power is The machine works normally. Below, the company briefly introduces the advantages of the diesel generator set. Diesel generator set parallel advantages: 1. Maintenance, maintenance is more convenient for multiple units to use in parallel, can centrally dispatch, allocate active load and reactive load, can make maintenance, maintenance is convenient. 2, more economical, can put the small power unit of the appropriate table according to the size of the online load, to reduce the fuel and oil waste of the small load operation of high-power units. 3,
  • Jan
    22
    The reason for the black smoke during the operation of diesel generator
    Insufficient engine power and continuous black smoke is excessive from most cylinders or all cylinders of the engine, and the fuel and air mixing ratio are disordered. When combustion, severe hypoxia, diesel combustion is incomplete, suspended free carbon elements The exhaust gas is formed together. If the exhaust pipe is intermittent black smoke, it is accompanied by \"Suscitation \", indicating that the individual cylinder is not complete. The main reasons have the following points: 1. Improper injection pump is quenched, so that the oil supply is too large, the combustion is incomplete. 2, the injection quality of most injectors is poor. 3, the oil supply is incomplete. 4, the opening of the intake door is lowered, the opening time is postponed, resulting in insufficient intake. 5, the air filter filter is too dirty or the air filter is installed, which is not smooth. 6. The supercharging efficiency of the supercharger is lowered. 7, the air quality is too bad. Jiangsu Xingguang Power Equipment Co., Ltd. founded in 197
  • Jan
    22
    Six of the Xinjiang Uygur Autonomous Region, the purchase of diesel generator sets
    On September 1, 2020, Jiangsu Xingguang Power Equipment Co., Ltd. signed a contract of diesel generator sets in a troops in Xinjiang Uygur Autonomous Region. The diesel generator set purchased was 150kw silent box. The model was XG-150GF, and the engine was Guangxi Yuchai YC6A245L-D21; the generator was Marathon MP-160-4A. Jiangsu Xingguang Power Equipment Co., Ltd. is responsible for the manufacture, transportation, commissioning, acceptance of the unit, and training customer unit operators. Jiangsu Xingguang Power Equipment Co., Ltd. was founded in 1974 and is one of the earlier manufacturers of domestic generator sets. There is a 64 sales service department in the country, which is ready to provide design, supply, commissioning, and repair a dragon service for users. Jiangsu Xingguang Company has been in 1982, has always been a manufacturer of generators in the\"National Internal Combustion Generator Set Quality Supervision and Inspection Center\". 2
  • Total 174 pages  Go to Page
  • Go
Urumqi Cummins Electromechanical Equipment Co., Ltd.
Urumqi Cummins Electromechanical Equipment Co., Ltd.
a professional production of generators.
Dieselgenerators Diesel generator setsManufacturers, Supply Cummins generator sets, Yuehai generator sets, Yuchai generator sets.
Contact Us
Address:Room 2-4-602, Jiafengyuan Community, No. 305, Beijing North Road, Urumqi, Xinjiang
Contact: Gu Xiaobing
Managed Office: +86-0991-3817210 +8618999222000
Sales: +86-0991-3814032 +8618609915083
Three packs: +86-0991-3814032 +8617704919966
Website:
www.xjxgdl.com
mailbox:3481400475@qq.com
Copyright ©Urumqi Cummins Electromechanical Equipment Co., Ltd.New ICP No. 17000509 -1