    Specific steps of the belt of the generator replacing the charging generator
    Generator replaces concrete step 1 of the belt of the charging generator, disconnect the main power switch and confirms that the engine has no other power supply 2, remove the cooling fan around the protective cover and the fan guide wind ring 3, and remove the transmission belt around the shield 4, Loosen the inner fixed bolts 5, and the kernel lock bolt allows the tension screw to be freely twezed. Loosen the tension screw and remove the drive belt More information to see the Starlight diesel generator set, you can also call after-sales service engineer 0991-3856119, 0991-3817210, 0991-3814032, 400-0991036
  • Mar
    29
    Precautions for start-ups with external auxiliary batteries
    Xinjiang Star Power Generator Technical Department tells you the precautions for the start of the generator sets. Warning Tips: The battery (especially the additional auxiliary battery) has an extremely explosive hydrogen oxygen gas, and if an additional auxiliary battery wiring is wrong, the spark is generated. It is sufficient to cause equipment damage or personal injury 1 to ensure that the grounding voltage of the junction of the additional auxiliary battery is consistent with the system voltage of the engine, first connecting one end of the red auxiliary cable (+) to an additional auxiliary On the battery, then connect the other end to the downtown digestive battery, and then connect a black auxiliary cable (-) on an additional auxiliary battery, and then connect the other end to the power storage battery having a certain distance. Locally, such as an negative electrode cable on the main power switch or on the negative electrode cable connector of the motor. 3, start the engine warning Tip: Do not touch the joint when trying to start the engine (there is a spark
  • Mar
    29
    How to replace Volvo engine lubricant consultation 13809953146
    How to replace Volvo engine lubricants Consulting Star Diesel Generator Unit Technical Department Zhou Feng collar 18609915083, 1999222000, 13809953146 Warning Tips: High temperature lubricants will cause severe burns 1, will put on oil hose to pick up the oil and pick up the oil, the soldiers ensure Do not leak 2, pumped out of lubricant (or removing the oil sputum release lubricant) Note: The lubricating oil used by the mobile phone and processes it to the waste oil recovery site, remove the oil hose (or install Put the oil plug) 4, add new lubricants more related information: www.xjxgdl.com Technical support website 0991-38561199, 0991-3817210, 0991-3814032, 400-0991036
  • Mar
    29
    How to replace the lubricant filter / bypass filter? Consultation Starlight Technology Department 18999222000
    How to replace the lubricant filter / bypass filter? Our company's technical service department tells you! WARNING: High temperature lubricants can cause severe burns 1. Clear lubricating oil filter holder 2, remove all lubricating oil filter 3, clear filter base cover with a suitable filter wrench, clear filter base cover, ensure that there is no seal The loop residue 4, a layer of engine lubricating oil 5 is applied to the sealing ring of the new filter, install a new lubricating oil filter. Two full-stream filters should tighten 1/2 to 3/4 laps after their sealing surfaces are tightened. The bypass filter should be tightened 3/4 to 1 lap 6 after the sealing surface is tightened, add a lubricant, start the engine and run 20-30 seconds 7, stop, check the lubricant oil level and press Add 8, check lubrication Sealing of oil filter, our company supplies all generator parts, diesel filter, oil filter, air filter, welcome to consult Gu Xiaobing 1899222000, 1380995
  • Mar
    29
    How to replace a fuel filter with an inlet sensor
    How to replace the fuel filter with an inlet sensor? Our company's technical department gives you a solution! It is also possible to consult 18999222000, 13809953146, 186099150831, a cleaning fuel filter surrounding 2, if the water sensor 3, radiate the fuel filter 4, remove the fuel filter 5, clean filter The sealing surface 6 on the cleaner holder is advised to apply a layer of lubricating oil in the pilot, and the new fuel filter 7 is installed on the filter, and the inlet water sensor 8 is connected, and the engine is activated and the engine is started. Leak more related information to see the generator set technology network: www.xjxgdl.com 0991-3856119, 0991-3817210, 0991-3814032
  • Mar
    29
    How to replace the coolant filter? Consulting Starlight Technology Department 18609915083
    How to replace the coolant filter? Consulting Starlight Technology No. 0991-3856119, 0991-3817210, 0991-3814032 The specific steps are as follows: 1, turn the valve to 90 degrees to prevent the coolant by the filter 2 of the coolant 2, remove the cooling with a suitable filter Liquid filter. It is ensured that there is no residue of the old seal on the base of the filter. 3. Shine a layer of engine lubricating oil on a new coolant filter seal ring. Use your hand to scroll the coolant filter, guide the sealing surface of the rubber seal primary filter, then the coolant filter is tightened by 1/2 lap 4, turn the valve (1) 90 degrees to re-let the coolant By the filter 5, the engine is activated, and there is no leak 6, and the championship is stopped to check the coolant level. Please refer to \"Check the Coolant Body Bit \". See you more information: www.xjxgdl.com 18999222000
  • Mar
    29
    Engine prevention and control of coolant
    Our company's technical service department tells the majority of customers to take advantage of the engine when the coolant is taken. Warning Tips: Do not open the coolant hemata when the engine is high temperature, and the steam or high temperature coolant will spray it out when the engine is high temperature. Liquid port 2, open all draft valves. The coolant in the heat sink is discharged with a water hose, and the discharge valve is located below the heat sink. 3. Make sure all of the coolant has been taken. In the inner cavity of the discharge valve / water, it may be deposited, and it must be removed. Otherwise, the coolant will remain in the engine, causing serious damage, check if the low point of each coolant system is equipped with additional water absorption valve, clogging each of the extension valve, reloading more related information. Star Power Generator official website: www.xjxgdl.com Details Consultation Technology: 0991-3856119, 0991-3817210, 0991-3817210, 0991-3814032
  • Mar
    29
    Precautions when generator electrical system operation
    When the generator is electrical system operation, it is necessary to pay attention to: (1) Turn off the power supply, and must shut down the engine before checking or repairing the electrical system, and disconnecting the power switch with the main power switch / circuit breaker. Outside power supplies for engine heaters, battery chargers, or other devices on the mounting engine must be disconnected, (2) a highly corrosive electrolyte in the battery N. Protect your eyes, skin and clothes when the battery is charged or handled. Remember to wear protective eyes and gloves. If the battery electrolyte is touched to the skin, it should be rinsed with a lot of water and soap. In case the primary eye of the electrolyte, we must immediately use a lot of clear rinsing and seek medical assist as soon as possible.
  • Mar
    29
    Walwaver generators are running in 10 hours within operation
    The Volvo engine must perform the following \"Rust\": 1, start the engine according to the normal operation. Don't let the engine run under full load unless time is short. Do not operate the engine in a constant rotational speed during the running combination. 2, during the 100-200 hours of operation, the lubrication fuel consumption is slightly higher, so it is more often checked more often than the usual recommendation. 3. When there is a separated clutch, it is necessary to make more careful inspections in the initial run, and it is possible to adjust to compensate for the initial running of the clutch tablet. More related information consulted with our company after-sales service department: 0991-3856119, 0991-3817210, 0991-3817210, 0991-3814032, 400-0991036
  • Mar
    29
    What is the characteristics of the automatic high pressure and connected unit?
    What is the characteristics of the automatic high pressure and connected unit? Now our company's after-sales service department technicians give you a solution feature: a, improve the flexibility of the power system. The unit parallel, easy to increase and reduce the number of units in the case of current electricity, and users need to maintain or other special circumstances, users can easily arrange the entire power system. B, reduce energy consumption, full life cost. For a long-term device such as a generator set, it is not only to consider the cost of purchase, but also considering the full life cost. During the actual use of the parallelepiration system, the user can select the number of units, saves the number according to the size of the electricity. Fuel, compared with a single large power unit, the spare parts of the small unit are easy to purchase. The price is relatively inexpensive, the maintenance cost is relatively low, so the full-service life cost of the parallel operation is relatively low. C and improve the power supply safety of important equipment. If one or some unit occurs in the parallel system
  • Total 53 pages  Go to Page
  • Go
Urumqi Cummins Electromechanical Equipment Co., Ltd.
Urumqi Cummins Electromechanical Equipment Co., Ltd.
a professional production of generators.
Dieselgenerators Diesel generator setsManufacturers, Supply Cummins generator sets, Yuehai generator sets, Yuchai generator sets.
Contact Us
Address:Room 2-4-602, Jiafengyuan Community, No. 305, Beijing North Road, Urumqi, Xinjiang
Contact: Gu Xiaobing
Managed Office: +86-0991-3817210 +8618999222000
Sales: +86-0991-3814032 +8618609915083
Three packs: +86-0991-3814032 +8617704919966
Website:
www.xjxgdl.com
mailbox:3481400475@qq.com
Copyright ©Urumqi Cummins Electromechanical Equipment Co., Ltd.New ICP No. 17000509 -1