1 First check the cylinder crankcase joint and tubing joints, such as inorganic oil leakage, and whether the oil seal is sealed before and after the crankshaft. If the oil sump is found to be infiltrated with the binding surface of the crankcase, the oil housing screw is fastened, and the liner is good, and the pressure in the crankcase is too high.
2 Take the oil ruler, if the pressure of the crankcase is indeed too high, it can be considered to be clogged by the crankcase ventilation device, and the dredging must be performed.
3 If the oil seal can be severely damaged before and after the crankshaft, it should be repaired in time. If it is just seepage, it can still be used temporarily, and it will be excluded from the secondary maintenance, but it should always pay attention to the oil surface height.
4 If there is a lot of oil in the air in the gas tube, there are many oils, the air compressor is blowing oil. The air compressor piston should be checked, whether the wear of the piston ring and the cylinder wall is too much, and it is repaired.
5 If the exhaust of the engine is blue, the oil is discharged by the oil-in-cylinder burn. It should first check that there is inorganic oil in the intake pipe. If an organic oil indicates that the sealing ring of the pressurizer is damaged, the oil will flow into the airway and need to replace the seal.
6 Check if the valve oil seal is intact, whether the fitting clearance of the intake gate rod and the catheter is too large, and replacing the repair.
7 If the above examination is good, then remove the cylinder head and the oil bottom shell, perform a comprehensive examination of the cylinder, piston, and piston ring, and achieve the purpose of the troubleshooting.
8 Check if there is an oil in the coolant, if there is, the cylinder or cylinder head is crackd from the cylinder or the cylinder head or damage to the oil cooler, so that the oil oil enters the coolant, it should be found to be repaired.
More related technical issues can consult our company technical engineering department: 0991-3856119, 0991-3817210, 0991-3817210, 0991-3814032, 40-0991036

Urumqi Cummins Electromechanical Equipment Co., Ltd.
Urumqi Cummins Electromechanical Equipment Co., Ltd.
a professional production of generators.
Dieselgenerators Diesel generator setsManufacturers, Supply Cummins generator sets, Yuehai generator sets, Yuchai generator sets.
Contact Us
Address:Room 2-4-602, Jiafengyuan Community, No. 305, Beijing North Road, Urumqi, Xinjiang
Contact: Gu Xiaobing
Managed Office: +86-0991-3817210 +8618999222000
Sales: +86-0991-3814032 +8618609915083
Three packs: +86-0991-3814032 +8617704919966
Website:
www.xjxgdl.com
mailbox:3481400475@qq.com
Copyright ©Urumqi Cummins Electromechanical Equipment Co., Ltd.New ICP No. 17000509 -1