1, the heat sink heat sink is blocked. Handling method: find the cause of the problem, cleaning the heat sink;
2, the coolant is insufficient. Treatment method: Add a coolant;
3, the cooling liquid fan is not working properly. Handling method: Check the fan belt tension, replace the new belt if necessary;
4, the radiator is not very ventilated. Treatment: Increase the effective area of ​​ventilation according to the installation requirements to ensure smooth ventilation;
5, coolant alarm switch (sensor) or instrument fault. Processing: Check the control screen, instrument, body sensor; repair or replace the equipment, troubleshoot;
6, fan damage. Handling method: overhaul or replacement;
7, the water pump is damaged. Handling method: overhaul or replacement;
8, the thermostat fault. Processing method: replacement;
9, fuel injection pump fault. Treatment method: maintenance personnel inspection or replacement;
10, the oil supply is not correct. Treatment method: View the fuel injection pump data and please maintenance staff to repair;
11, the environment (intake) temperature is too high. Treatment method: Keep the machine room to reasonably reduce the temperature of the equipment room;
12. The unit is overloaded. Processing method: Control the load, prohibiting machine groups overload operation.

Jiangsu Xingguang Power Equipment Co., Ltd. was founded in 1974 and is one of the earlier manufacturers of domestic generator sets. There is a 64 sales service department in the country, which is ready to provide design, supply, commissioning, and repair a dragon service for users. Since 1982, the company has always been the\"National Internal Combustion Engine Generator Group Quality Supervision and Inspection Center\". At the end of 2001, the product quality passed ISO9001 standard certification. The Xinjiang Office of the Company was established in 1995 and has long-term imports, joint ventures, domestic diesel generators and spare parts for the majority of customers for 30KW-2000KW. support hotline:18999222000!


Urumqi Cummins Electromechanical Equipment Co., Ltd.
Urumqi Cummins Electromechanical Equipment Co., Ltd.
a professional production of generators.
Dieselgenerators Diesel generator setsManufacturers, Supply Cummins generator sets, Yuehai generator sets, Yuchai generator sets.
Contact Us
Address:Room 2-4-602, Jiafengyuan Community, No. 305, Beijing North Road, Urumqi, Xinjiang
Contact: Gu Xiaobing
Managed Office: +86-0991-3817210 +8618999222000
Sales: +86-0991-3814032 +8618609915083
Three packs: +86-0991-3814032 +8617704919966
Website:
www.xjxgdl.com
mailbox:3481400475@qq.com
Copyright ©Urumqi Cummins Electromechanical Equipment Co., Ltd.New ICP No. 17000509 -1