Why can the throttle adjust the output current of the generator?
Views: 0 Author: Site Editor Publish Time: 2013-04-01 Origin: Site
The output current of the generator is determined by the voltage and load of the machine. Since the loading of the load and the battery is constantly changing as the operating state of the engine is constantly changing, it is not easy to adjust. If the size of the current to output the current is easier to implement by adjusting the voltage.
The working principle of the throttle is that when the generator output current exceeds the rated value, the voltage of the generator is lowered, so that the output current must not exceed the specified value. The method of reducing the voltage of the generator is the same as the compression. The difference is that the iron core coil of the throttle is concatenated with the armature coil, and the suction of the coil is varied as the size of the generator output current.