Views: 0 Author: Site Editor Publish Time: 2015-04-12 Origin: Site
At present, diesel generator sets are the main power generation tools used in many units, especially in engineering, and more used in diesel generator sets. This makes the price of diesel generators on the market. Diesel generator sets The difficulty of starting, mainly diesel causing calenders, and diesel have been brought into cylinders but still start difficulties. When the diesel generator set, we must first identify the reason so that we can avoid malfunctions as much as possible. Now, Jiangsu Xinglu generator manufacturers introduce how to deal with the difficulty of the diesel generator startup:
I. Difficulties in the starting of diesel without air cylinder
The diesel engine is operated at the start of the starter, but the diesel engine cannot be started, and there is no explosive sound. There is no diesel flavor and smoke discharge, which means that the diesel does not enter the cylinder. The reasons that cause this happen:
1. Oil in the tank, the fuel tank switch is not turned on or the flameout button is not returned;
2, the fuel injection pump supply rod card, there is air in the oil road, the filter is blocked, and the hose is distorted, bending, etc.
3, the oil filter is blocked by the oil pump, and there is water in the oil road to cause winter frozen and diesel grades, such as the use of summer oil in winter, diesel will condense the stone, and block the oil road;
4, the injector needle valve is caught injectable oil, the injection pump drive gear damage and the injection pump cam shaft tank or semi-circular bond is damaged.
Second, diesel has entered the cylinder but still start difficult
The diesel engine can hear intermittent explosive sound under the driving of the starter motor, and the exhaust pipe has a diesel flavor, white smoke or a small amount of black smoke, and the diesel has entered the cylinder. If it is still unable to start or start difficult, it may be:
1. The fixed bolt between the coupling active disk and the active flange is loose, resulting in too late oil supply time;
2, the low-pressure oil circuit returns the roll spring excessively or damaged, resulting in too low oil supply pressure, fuel injection pump outlet or plunger deputy, resulting in excessive injection
3, the injector needle valve is damaged or the pressure regulating spring is damaged, which makes the diesel spray mass, and the diesel contains moisture, so that the diesel is not easy to combust, the air filter is blocked, causing insufficient intake;
4, the exhaust brake valve is not opened, so that the exhaust is not smooth, causing exhaust gas;
5, the valve gap is adjusted or ablated, the piston ring is worn, the injector is fixed tight with the seat hole, and the cylinder head bolt is loose.
Our company sells various brands, models, specific diesel generators all year round, and provides after-sales service. Service Hotline: 0991-3856119 0991-3817210 0991-3814032 13809953146 18999222000 18609915083 4000991036