Views: 0 Author: Site Editor Publish Time: 2014-04-08 Origin: Site
Is the diesel generator group boot directly? The answer is not possible, then dieselGenerator setWhat need to do before starting, what do you need to do?
Our company's after-sales service department is summarized as follows: Since the generator set with an automatic control system can be automatically started until the warning is warned, turn it off before the check is checked. 1, when the coolant is still hot, do not open the heat sink cover, do not add a large amount of liquid in the hot cooling system, and whether it will cause serious damage. Put the control switch power / emergency stop. 2, check the diesel engine oil and cooling level, it is not enough to complete it. When the fuel is injected into the fuel tank, don't smoke or use an open flame, check if the oil is cleaned. 3. Check the fuel level and add it. 4, check the diesel cooling fan and the charging belt, such as the tightening. 5, check all hoses to see if the binding is loose, off, damaged, wear, if it is tightened or replaced. 6. Check the battery electrode has no rot, it is cleaned. 7. Check the battery level, if necessary, add distilled water if the battery is new, and never rush over electricity, add a pre-equipped battery. 8, check the control screen andgeneratorWhether there is a large amount of dust and dirt, these dust and dirt can cause electric shock or cause the cooling to cause problems. 9. Check the blocker indicator of the air filter, if it is blocked, it is necessary to return to a filter. 10. To clean up in power generation and surrounding venues, the unsafe objects should be moved to avoid affecting operation or happening. Make sure the cooling ventilation is not blocked. 11. Check the fuel system, cooling system and lubricant oil seal in the unit. 12. The exhaust system has a drain valve to regularly discharge the cohesive moisture. 13. Make sure the AC generator output circuit switch is in the off state (downward down) 14, check the lubricant oil level, need to add
Technical support hotline: 0991-3856119, 0991-3817210, 0991-3814032, 40-0991036