Diesel generator setsHow long is the service life? In fact, the length of life of the generator set also depends on how to use it correctly, if used in accordance with the skills used, it will directly increase its life time. First, it is clear that the three types of air filter, oil filter and diesel filter in the veneer, to extend the service life of the diesel generator, during use, To strengthen the maintenance of air filter, oil filter and diesel filter, give full play to their role. Air filter is not allowable, reverse or missed at each sealing gasket and rubber connecting tube when installing, and ensures the rigidity of each embedded. The paper dust cup air filter is used, 50-100 hours, to remove dust, can be brushed away from the surface of the surface with a soft brush, if the working time exceeds 500 hours or is damaged, it should be replaced in time. With an oil-type air filter, each work is 100-200 hours, the cleaned diesel cleaning the filter is applied, and the oil is replaced, if the filter is broken, it will be replaced immediately, and pay attention to the use of oil. The oil filter is not in time, the filter element is blocked, the oil pressure is increased, the safety valve is opened, and the lubricating oil is directly infined, which will exacerbate the wear of the lubrication surface, affect the service life of the diesel generator set. Therefore, every 180-200 hours of engine oil filter, it is necessary to wash once, discovering damage, should be replaced immediately to prevent impurities from entering the lubrication surface. Diesel generator sets, the crankcase and each lubrication surface should also be cleaned, and the method is to wash the oil after mixing with oil, kerosene and diesel. After the oil is released, the wash oil is cleaned, then the diesel generator sets 3-5 Minute, let's put it, add new oil. The various fuel filters in the fuel supply system should be removed once every 100-200 hours, and the debris and the oil tank and various oil pipelines are fully cleaned. When cleaning the filter and seals, it should be special carefully, and it is broken, it needs to be replaced in time. When transitioning in the season, the components of the entire fuel supply system should be cleaned. Diesel uses should meet the seasonal requirements and require 48 hours of precipitation purification treatment. Note: The three filter of air filter, oil filter and fuel filters are losses, and it is necessary to replace new. This will better extend the service life of diesel generator sets.