How long does the diesel generator set need to maintain maintenance?

Views: 0     Author: Site Editor     Publish Time: 2014-04-08      Origin: Site

After a period of use, the diesel generator set is maintained after a period of maintenance, so that the downtown oil generator group can eliminate the hazards in the diesel generator set, and ensure that the unit is in a good working condition, and can extend the service life, our companyDiesel generator setsThe maintenance cycle make the following summary, please see the users!

Note: 1. Diesel generator set maintenance cycle calculates working hours and calendar times, and the provisions are scheduled for both

2. The customer should check and maintain in advance according to the actual operation of the diesel generator set. The maintenance cycle and maintenance items of the engine should be appropriately adjusted according to the purpose, the use of conditions, and the performance of the fuel, and the performance of the lubricants.

3. The spare diesel generator set requires a good spare state that is rapidly started and input, so it is required to implement a regular examination and the following trial operation.

4, the following symbol representative meanings, 1 represents overhaul, cleaning, adjustment, etc .; 2 represents the replacement of the generator set spare parts; 3 representatives can contact suppliers or manufacturers when customers cannot overhaul; 4 represent new machines, big repair Diesel generator sets after the short-term deposit, the maintenance items needed in the initial 50 working hours.

Engine maintenance test runRun 5-10 minutes per week

Check: Start performance, lubrication oil pressure, exhaust gas color, vibration, etc.

Take a proper amount of load for 15-30 minutes per week

Diesel generator setsMaintenance cycle table

Check itemevery day50 working hours or monthly250 working hours or every March400 working hours or every June600 working hours / annual1200 working hours or every 2 yearswhen necessary
Check lubricants and water levels

1







Check fuel filter

1







Check air filter cleaning indicator

1







Check the boot battery

1





Replace oil and oil filter

2





Check the V-strap tension

1





Adjust the valve clearance


1




Cleaning crankcase exhaust pipe



1



Check the Organs and Links



1



Replace the fuel filter



2



Analysis of cooling water content



3

Check / repair the energetic system



1



Check the cooling system



1



Engine adjustment




3


Check the diesel speed, adjustable




1
Tuning engine valve clearance




1


Check the fuel system




1


Check turbo pressurizer system




1


Cleaning the cooling system, replace the thermostat




3


Gold fork air filter, must be replaced





4


Urumqi Cummins Electromechanical Equipment Co., Ltd.
Urumqi Cummins Electromechanical Equipment Co., Ltd.
a professional production of generators.
Dieselgenerators Diesel generator setsManufacturers, Supply Cummins generator sets, Yuehai generator sets, Yuchai generator sets.
Brand generator set recommended
Contact Us
Address:Room 2-4-602, Jiafengyuan Community, No. 305, Beijing North Road, Urumqi, Xinjiang
Contact: Gu Xiaobing
Managed Office: +86-0991-3817210 +8618999222000
Sales: +86-0991-3814032 +8618609915083
Three packs: +86-0991-3814032 +8617704919966
Website:
www.xjxgdl.com
mailbox: 3481400475@qq.com
Copyright ©Urumqi Cummins Electromechanical Equipment Co., Ltd. New ICP No. 17000509 -1