Cummins diesel generator set structure characteristics: DC power start, four stroke, water cooling, self-belling fan, closed circulation cooling, intake air, cold, exhaust gas turbine boost. The cylinder design is rugged, small vibration, small noise, straight four stroke, smooth operation: replaceable cylinder block, long life, convenient maintenance; two cylinders, 4 valves per cylinder, full, excellent performance Forced water, heat radiation. Compared with domestic similar products, there is a small weight, low fuel consumption, high power, reliable work, and convenient accessories. With electronic governors, there is a protective function of too high cooling water, low oil pressure and speed alarm and automatic parking. Users need to use it for the installation of Cummins diesel generator sets: ● The unit installation location needs to be well ventilated, and the generator side should have enough air outlets, and the diesel engine should have a good ventilation. The exit area should be more than 1.5 times the area of the water tank. ● Wheel around the installation should be cleaned to avoid placing an article that produces an acidic, alkaline etchible gas and steam nearby. Conditional should be configured. ● If the user is in indoor use, the exhaust pipe must be opened outdoors, the pipe diameter must ≥ the tube diameter of the muffler, the elbow of the pipeline should not exceed 3, to ensure the smoke, and should Tilt down 5-10 degrees down, avoid rain injection; if the exhaust pipe is installed vertically, the rain cover must be installed. ● When the basal is used, the level is required to measure the horizontal level at the time of installation, and the unit is fixed to the horizontal basis. There should be a special shockpress or a foot bolt between the unit and the foundation. ● The unit enclosure must have a reliable protective ground, and the generator that needs to be directly grounded, it must be neutral grounded by the professional, and the lightning protection device is configured, which is strictly prohibited to use the main grounding device of the mains to carry out the neutral point directly. Ground. ● The two-way switch of the generator and the main electricity must be very reliable to prevent electricity.
Diesel generator set sales hotline: 18999222000 18609915083 13809953146
If there is related technical questions, please contact our company: 0991-3817210 0991-3856119 0991-3814032