1. The battery is recharged by the charging generator mounted on the diesel engine during use, and the charge is automatically adjusted by the generator regulator.
2. After the battery is discharged, charging should be charged in the shortest time to avoid a plate sulfurization.
3, the air hole of the battery fluid gas plug should be smooth, and the charging should be unshed, and the charging should be screwed.
4, the height of the battery electrolytic liquid should be checked, generally should be 10 to 15 mm above the top surface of the plate, and the ratio of dilute sulfuric acid or distilled water having a weight of 1.400 should be fed when it is not normal.
5. The unused battery has been charged, and at least once a month.
6, the battery should be kept clean, regularly scrub the leakage surface, the vent hole and the wire joint on the ventilator cover. When cleaning should be aware that the cleaning liquid into the battery and prevents the debris from entering the electrolyte.
7, the battery is often charged, long-term discharge, excessive discharge or discharge is not timely charge, can cause the battery plate sulfate, characterized in that a large white sulfate layer is generated at the top of the plate, affecting the battery. Charge and discharge performance.
8. When using the battery in the cold area, you should pay attention to the insulation and appropriately increase the specific gravity of the electrolyte to prevent freezing due to the specific weight of the electrolyte.
9. When the barrier of the battery is damaged or the conductive metal is inserted into the battery or the bottom precipitate accumulates too much, the battery can be short-circuited, resulting in the electrolyte specific gravity at the time of charging, and the temperature is high, the temperature is very low, and the charging voltage is very low and discharge The phenomenon of the voltage is lower.
10. If the battery isolation plate, battery tank and cover should be sent to the professional unit repair or change.
11. When the battery is used at a low temperature environment, since the discharge performance of the battery is deteriorated and the starting motor is increased, if the discharge capacity of the motor is not enough, two pairs of batteries can be connected in parallel, and the 24V voltage is maintained. To increase the current capacity of the battery.
To learn more, maintenance, maintenance technology calls to our company: 18999222000 138099953146 18609915083 0991-3817210 0991-3814032 0991-3856119 400-0991036

Urumqi Cummins Electromechanical Equipment Co., Ltd.
Urumqi Cummins Electromechanical Equipment Co., Ltd.
a professional production of generators.
Dieselgenerators Diesel generator setsManufacturers, Supply Cummins generator sets, Yuehai generator sets, Yuchai generator sets.
Brand generator set recommended
Contact Us
Address:Room 2-4-602, Jiafengyuan Community, No. 305, Beijing North Road, Urumqi, Xinjiang
Contact: Gu Xiaobing
Managed Office: +86-0991-3817210 +8618999222000
Sales: +86-0991-3814032 +8618609915083
Three packs: +86-0991-3814032 +8617704919966
Website:
www.xjxgdl.com
mailbox: 3481400475@qq.com
Copyright ©Urumqi Cummins Electromechanical Equipment Co., Ltd. New ICP No. 17000509 -1